Set cassette #2 correctly 2. Check dispensed check and reject check.2. Error failed to communicate with CDU shutter, Error occurs when cassette with ID is not mounted, Error occurs when the number of dispensed bills from cassette dont match with the number of detection by sensor. New! Hyosung America is the leader in banking and retail solutions and provider of industry-leading branch transformation and self-service solutions for banks and retail businesses of all sizes. Check if CS62 sensor poll is abnormal 3. ATM MACHINES USA COMPANY Copyright All rights reserved. Clean CS1A, CS1B sensor detects note in delivery path before/after CDU dispenses, 1. Tranax and Nautilus Hyosung ATM Printer Paper Roll, Nautilus Hyosung Reject Gate Solenoid Assembly, Nautilus Hyosung Function Key Rubber Cap - Halo Series, 07/28/21 - Genmega Update Notice Reminder. Remove dust in CS15AB, CS31AB, CS41AB CS1AB Sensor 4. Check CS5_2 Sensor Cable 2. Check notes dispensed and rejected 2. Our strategic alliances with our ATM processors, ATM manufacturers, and other partners have allowed us to grow and maintain a level of service that exceeds the expectations of our customers. Initialize after Reset Power 2. If so, remove them. Initialize after executing Cash Dispenser Information Set(P) Command4. Remove foreign objects in the shutter unit. Clear (Sender) Compatiblity: All Nautilus Hyosung Dispensers (CS2, CS13, CS4, CS1, CS15, CS41) View. Check if the CIU power cable is connected. Cash Dispenser EP Program Error during dispense operation (failed table search), 1. Check logic related to the jam detection sensor of the Slip Printer board. Email a friend. 3. Check notes in Reject Box2. SKU . HOST tried to communicate with IC card without card activation. Check if CS62 sensor poll is abnormal3. . ICRW detects time out. Remove any jammed bills from the dispenser, if no bills are present try using compressed air to clean the dispenser (a sensor may be blocked by dust). Nautilus Hyosung Halo II ATM Machine Cassettes Check the status of sensor and its connector, 1. To show that write error is detected through write/verify procedure. 3.2 Component Location of MoniMax 5600 without . Remove jammed paper between printer head and rollers . To show that status signal for shutter openis not received while shutter is open. Exchange a sensor after abnormal operating CS3 Gate detecting sensor. Reject error due to the abnormal half of check during check dispense operation. Check notes in Reject Box 2. 1. Hyosung Optical Sensor (Receiver) C0056. Check Main Motor Encoder Slit 3. Remove notes on CS2 sensor 2. Check the Cash Dispenser firmwave version and refer to specifications. 2. No sensing black mark (dark sensor) The size of image print data is abnormal . Clean CS4A, CS2 or CS4A sensor detects note in delivery path before/after CDU dispenses, 1. If you're processing with Prineta and need help - call us at 800-951-9533 and our ATM technician can help you resolve your issue over the phone at no cost! Close the lever of print head completely, 1. ATM Error Codes on Hyosung & GenMega Machines | Prineta USA | Prineta CS13 Sensor 3. install after rearranging notes in cassette 40063 The remaining notes at the sensor in front of the 3rd CST after dispense operation(CS31AB) 1. Nautilus Hyosung Error Codes Don't forget to protect your ATM Machine with the ATM Shield Line of Products! Check communication cable 3. Call your attendant, Pinpad (EPP) is down when it receives an Initializing command, EPP is down when it receives an Get Status command, EPP is down when it receives an Clear Func Key command, ** Reference https://hyosungamericas.com/. To show that the ejected card has not been withdrawn during execution of Monitoring for removal command. Check if each sensor is mounted. PDF MX-5300CE Error Code V01.00.05 Check if communication cable or COM port is not connected, Check if communication cable or COM port is not connected, 1. Model: Nautilus Hyosung MX5000CE MX5200T MX7000T NH1800SE NH2700T MX4000W MX5000SE NH2700CE MX5300XP NH1800CE NH1500 MX5100T. Check index value of notes each cassette, In case the number of notes detected outlet sensor(CS13) is less than the number of required notes, 1. Remove dust in CS1AB, CS15AB, CS31AB,CS41AB Sensor4. hyosung ce error codes Rearrange notes in Cassette 3. Hyosung 1K CDU Sensor Locations. Replenish receipt paper in paper charger2. Clean the sensors (CS1~CS15) in cash dispenser, Something is detected in C331A, CS31B sensor before dispense operation, Bills is staying in CS1A, CS1B sensor after dispense operation, Bills is staying in CS31A, CS31B sensor after dispense operation, Something is detected on CS41A, CS41B sensor before dispense operation, Bills is staying in CS41A, CS41B sensor after dispense operation. Get the trace file and log files in D:\trace 2. Nautilus Hyosung NH2700CE ATM Machine CDU (Dispenser) Failure at IC Contact solenoid or sensor ICD. Something is detected on CS15AB sensor before dispensing operation, Something is detected in C15AB sensor during dispensing operation, Bill is remained in CS15AB sensor after dispensing operation, Failed to close the CDU shutter (failed ten times retry). Check dust existing in CS5 Sensor Guide 5. Hyosung Double Detect Support for Removable Cassette CDUs, ATMPartMart Double Detect Roller for New Style 1k CDU, Roller Only, ATMPartMart Replacement EMV Card Reader - For Multiple Hyosung Models, Hyosung Reject Bin Cover for Newer Style 1K CDUs, Hyosung 1K Old Style CDU Controller Board for NH 1800, 1800CE, 1500, MX 5000CE, Hyosung Drawer Style LS7/LS8 Coupling Sensorw/ Bracket, Hyosung 2K and Above CDU Controller Board for Halo II, 2800SE (FORCE), 2700CE & More, Hyosung 1K New Style CDU Reject Gate Solenoid, Hyosung Coupling Sensor w/ Bracket CS3/CS8 For All Removable Cassette CDUs, ATMPartMart EMV Upgrade Kit for Halo & Halo S, ATMPartMart Extra Durable Blue Belt Series Dispenser Feed Belt, Small (Size: 14x344), For 2K Note Dispenser, Hyosung WinCE 7.0 Integrated Mainboard I/O Board For 2800SE (FORCE), 2700CE & More, Hyosung Reject Solenoid Assembly for Removable Cassette CDUs, Hyosung New Revision Exit Gate Solenoid for 2K, 4K, 6K & 8K CDUs, Hyosung Cortex Mainboard For Halo II, 2800SE, 2700CE, 1500SE & More, Hyosung Clutch Spring for Removable Cassette Dispensers, Hyosung Exit Gate Solenoid Spring For 2K, 4K, 6K, 8K, Drawer Style CDUs, Hyosung Drawer Style CDU Controller Board For Halo II, 2700CE, 1800SE & More, Hyosung Drive Belt for 2K CDU & Above (Size: S3Mx453), Anti-Static Brush & Bracket For MCDU, SCDU & TCDU Latest Version, Repair of Hyosung Dispenser Mainboard 1500, 1800SE, 1800CE, 2700CE & More, Hyosung Reject Solenoid Spring For 1K & 2K Dispensers, Hyosung Optical Sensor, Receiver For Dispenser. Check the printer head and change if necessary. 2. Check if the CS62 sensor cable is disconnected (Cash Dispenser Board CN10 #5~2). Copyright Nautilus Hyosung Inc. 2009 All right reserved, Ssl/tls configuration guide using dpl's hercules wireless modem (12 pages), Manual will be automatically added to "My Manuals", Operating and Changing the Electronic Combination Lock, Cash Counter HYOSUNG MONiMAX8100T Operator's Manual, Cash Counter HYOSUNG 2700CE Owner's Manual, Cash Counter HYOSUNG MONiSAFE500S Operator's Manual, Cash Counter HYOSUNG MONiMAX8100QTN Operator's Manual, Cash Counter HYOSUNG MoneyMax MX2600SE Configuration Manual, Cash Counter HYOSUNG NH-2700CE Operator's Manual, Cash Counter HYOSUNG NH-1800CE Operator's Manual, Cash Counter HYOSUNG NH-2700 Operator's Manual, Cash Counter HYOSUNG NH-2700T Operator's Manual, Cash Counter HYOSUNG MX-4000W Operator's Manual, Cash Counter HYOSUNG MONiMAX8300D Installation Manual, Cash Counter HYOSUNG MONiSAFE500S Installation Manual, Cash Counter HYOSUNG MoniMax7600 Installation Manual, Page 10: Description Of Precaution Symbols, Page 17: Spr (Slip Printer/Receipt Printer), Page 21: Ce (Control Electronics) : Iobp-945G, Page 22: Ce (Control Electronics) :Ecs Eg31M, Page 27: Opening And Closing The Security Door, Page 37: Emptying The Reject And Retract Box, Page 38: How To Clear Jamming In Cash Dispenser, Page 43: How To Clear Jamming In Receipt Printer, Page 107: Journal Paper And Ribbon Cassette, Page 109: Operating And Changing The Electronic Combination Lock. 2. TJ's Tip #5: How to Upload ATM Software. . Check the abnormal communication cable.3. Replenish receipt paper in paper charger2. Remove note from the CDU delivery path. You're in control. Check the abnormal communication cable. ICRW tried to activate with ICC/SAM, but the card returned ATR, which is not supported. Nautilus Hyosung Error Codes - Empire ATM Group Reconfigure cash dispenser setup data, Retract box position error during comman reserved operation. .more Price: $19.00 Buy Now Dispenser Plastic Lid To show that only SS,ES,LRC are contained in the track. Check if the CS3 sensor cable is disconnected(CN10 #9~10) 5. 2. Hyosung Optical Sensor (Receiver) Vendor Item #: S21685202. RocketATM is available to help | Our ATM tech team is only ONE phone call away at 1-855-444-4286, Models : NH 2700CE, MX 5300XP, NH 1800CE, NH 1500, MX 5100T, MX 5000CE, NH 2200, MX 7000T, NH 1800SE, NH 1800, NH 2700T, NH 5050, MX 5000SE, NH 2500, NH 1800POS, NH 1000, NH 2000, NH 2100T, NH 9030, MX 5100, MX 7000D, NH 2150, 5300CE. ATMPartMart is the industrys leading innovator, developing solutions to meet all of your ATM needs. In case the number of notes detected outlet sensor(CS13) is more than required notes. Check index value of notes each cassette, In case the number of notes detected outlet sensor(CS13) is less thanthe number of required notes, 1. Initialize 3. Exchange sensor after abnormal operating CS13 Sensor, 1. 2. Check if Dip switch # 6 is correctly set (Dip switch # 6 is set by On in case of not using Black mark), Sensor detects note in delivery path before CDU dispenses, CS4 sensor detects note in delivery path befoe CDU dispenses, Cash Dispenser(CDU) received the undefined command from AP software, 1. Remove note from the CDU delivery path. NextATM is the leading supplier of ATM machines, ATM parts, ATM signs, ATM decals and ATM . Clean CS1A and CS13, 1. CS2 and CS3 Dark detection during initializing or dispense reserved operation, The same as #40011 and #40012 error handling, CS4A sensor detects note in delivery path before/after CDU dispenses, 1. Hyosung ATM Error Codes | PDF | Automated Teller Machine | Financial Hyosung Optical Sensor, Receiver For Dispenser - ATMPartMart Check notes in 1 Cassette 2. Give it a try youre a few clicks away from Blast Off! Reject error due to short check sheet during check dispense operation. Double detect failure (During C0037 dispense) 1. Check the status of sensor and its connector . Check a checks status in the reject box 2. Replenish receipt paper2. Remove a jammed note at the position of the CS13 sensor3. . Remove dust in CS1AB, CS15AB, CS31AB, CS41AB Sensor 4. Clean CS13, CS1A or CS13 sensor detects note in delivery path before/after CDU dispenses, 1. NextATM is the leading supplier of ATM machines, ATM parts, ATM signs, ATM decals and ATM . ICRW tried to activate with ICC/SAM, but the card returned ATR, Which does not match EMV. Remove a dust or foreign objects . To show that a card was not inserted from the rear, even if 10 seconds had passed after the execution of BACK ENTRY command. Copyright Nautilus Hyosung Inc. 2009 All right reserved, Manual will be automatically added to "My Manuals", Cash Counter Nautilus Hyosung MoniMax 5100T Operator's Manual, Cash Counter Nautilus Hyosung Monimax 5300CE Installation Manual, Cash Counter Nautilus Hyosung MoniMax 7600T Installation Manual, Cash Counter Nautilus Hyosung MONiMAX5600 Service Manual, Cash Counter Nautilus Hyosung MX7600I Operator's Manual, Cash Counter Nautilus Hyosung MX8800 Operator's Manual, Cash Counter Nautilus Hyosung MS500 Operator's Manual, Cash Counter Nautilus Hyosung MONiMAX7800D Operator's Manual, Cash Counter Nautilus Hyosung MONiMAX5600T Operator's Manual, Cash Counter Nautilus Hyosung MONiMAX8800 Installation Manual, Cash Counter Nautilus Hyosung MONiMAX8200QTN Operator's Manual, Cash Counter Nautilus Hyosung MONiMAX7800T Installation Manual, Cash Counter Nautilus Hyosung MONiMAX7600TA Installation Manual, Cash Counter Nautilus Hyosung MONiMAX7800I Operator's Manual, Cash Counter Nautilus Hyosung MONiMAX7800I Installation Manual, Cash Counter Nautilus Hyosung MONiMAX8200QTN Installation Manual, Page 11: Description Of Precaution Symbols, Page 18: Spr (Slip Printer/Receipt Printer), Page 22: Ce (Control Electronics) : Iobp-945G, Page 23: Ce (Control Electronics) :Ecs Eg31M, Page 30: Opening And Closing The Security Door, Page 35: Opening And Closing The Front Panel, Page 41: Emptying The Reject And Retract Box, Page 42: How To Clear Jamming In Cash Dispenser, Page 47: How To Clear Jamming In Receipt Printer, Page 82: Journal Paper And Ribbon Cassette.